From 3233c91863f9e44bfa5ee984fcc15079f9f8032f Mon Sep 17 00:00:00 2001 From: Jun Zhang Date: Tue, 11 Feb 2025 19:53:42 +0800 Subject: [PATCH] bluez: fix rcu reconnect BT:fix BT Remote control disconnected after reboot.[1/1] PD#SWPL-89240 Problem: BT Remote control disconnected after reboot Solution: if have error do not add timer. Verify: T5D Change-Id: Ie4b1e2fa5a3966cfa95f6b9603a0651aa811c127 Signed-off-by: hong.wang --- src/shared/att.c | 6 ++++++ 1 file changed, 6 insertions(+) diff --git a/src/shared/att.c b/src/shared/att.c index f7bef08..9cce738 100644 --- a/src/shared/att.c +++ b/src/shared/att.c @@ -188,6 +188,7 @@ static uint8_t get_req_opcode(uint8_t rsp_opcode) struct att_send_op { unsigned int id; + unsigned int lastid; unsigned int timeout_id; enum att_op_type type; uint8_t opcode; @@ -582,6 +583,11 @@ static bool can_write_data(struct io *io, void *user_data) return true; } + if(op->id == 16 && op->lastid == 0) { + return true; + } + op->lastid = op->id; + timeout = new0(struct timeout_data, 1); timeout->chan = chan; timeout->id = op->id; -- 2.25.1